Sentix · Edge

Threat hunting where traffic can't leave the site

Sentix is an on-site appliance that runs Huntra-class detection on industrial and IoT networks. It learns each site's normal and sends findings upstream, never raw traffic.

Edge applianceExample

plant-03 · Sentix

Uptime
41 d 6 h
Assets seen
1,284
Protocols
Modbus, OPC UA
Findings today
2
Upstream link
offline, queued
Example. Values are illustrative.

Capabilities

What Sentix does

Detect

On-device, at line rate

GPU inference on the appliance keeps up with the site's traffic.

Understand

Industrial protocols

Behavioural models for Modbus, DNP3, OPC UA and PROFINET.

Baseline

Per-site normal

Each plant, substation or depot gets its own model of expected behaviour.

Enforce

In-path containment

With a BlueField DPU, Sentix can isolate a segment on site under your guardrails.

Operate

Offline and air-gapped

Works with no outbound connection; updates arrive by signed package.

Manage

Fleet updates

Push model and software updates to every site from one console.

How it works

Inside Sentix

  1. Mirror

    Connect to a SPAN port or tap on the OT network.

  2. Learn

    Build the site baseline over normal operating cycles.

  3. Detect

    Score traffic locally and raise findings.

  4. Forward

    Send findings to Veridex, or hold them on site when air-gapped.

Where it runs

Built for industrial environments

Manufacturing

Plants and lines

PLC and HMI traffic, engineering workstations and vendor remote access.

Energy and utilities

Substations and pumping stations

DNP3 and IEC protocols across remote, low-bandwidth sites.

Transport and logistics

Depots and robot fleets

Connected vehicles, AMRs and the networks that coordinate them.

Specification

Inputs, outputs and hardware

ItemDetail
HardwareNVIDIA Jetson Orin (NX, AGX) or IGX Orin, optional BlueField DPU
ProtocolsModbus/TCP, DNP3, OPC UA, PROFINET, EtherNet/IP, BACnet, plus standard IT protocols
ConnectionPassive SPAN or tap; in-path mode only with a DPU and explicit approval
UpstreamFindings and metadata only; raw traffic stays on site
SoftwareMorpheus, TensorRT, Holoscan, DOCA

Questions

About Sentix

Will Sentix disrupt our control network?

No. It listens passively on a mirror port by default. In-path enforcement is a separate mode you have to enable.

What if the site has no internet connection?

Sentix runs fully offline. Findings stay in its local console, and updates arrive as signed packages.

Does it support legacy equipment?

Yes. It only needs to see traffic, so it works with equipment that can't run agents.

Point Sentix at your own telemetry

We'll scope an assessment with you: which sources {name} would read, for how long, and what we'd report back.